28 results found.
7000 MASTER PROGRAMMING MODE WITH TIME OF DAY DISPLAY SET TO 12:01 P.M., PUSH AND HOLD SET UP AND SET DOWN BUTTON FOR 5 SECONDS. US/METRIC DISPLAY FORMAT EXAMPLE: GALLONS [U- -1] = DEFAULT LITERS [U- -2] NOTE: REGENERANT FLOW 1. SET TIME OF DAY DISPLAY TO 12:01 P.M. EXAMPLE: DOWNFLOW [DF] = DEFAULT 2. PUSH AND HOLD THE SET DOWN AND SET UP BUTTON FOR DOWNFLOW FILL FIRST [DFFF] 5 SECONDS. FILTER [FLTR] 3. PRESS EXTRA CYCLE BUTTON ONCE PER DISPLAY UNTIL ALL DISPLAYS ARE VIEWED AND NORMAL OPERATION IS RESUMED. REGENERATION TYPE 4. OPTION SETTING DISPLAY MAY BE CHANGED AS EXAMPLE: TIME CLOCK DE...
APS WATER M WATER SPECIALIST EE O CONTROL VALVE .C PROGRAMMING AND COVER DRAWING MANUAL ER AT W PS .A W W W APS WATER SERVICES CORP - 7320 VALJEAN AVE. VAN NUYS, CA 91406 - 800-460-9011 - WWW.APSWATER.COM PAGE 2 APS WATER EE MANUAL M O .C ER AT W PS .A W W W APS WATER SERVICES CORP - 7320 VALJEAN AVE. VAN NUYS, CA 91406 - 800-460-9011 - WWW.APSWATER.COM EE MANUAL APS WATER PAGE 3 TABLE OF CONTENTS M EE FRONT COVER AND DRIVE ASSEMBLY.................................................................................................................................. 4 REGENERATION AND ERROR SCRE...
MODEL 5600 MECHANICAL CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL NORYL®* INLET/OUTLET 3/4, 1, 1-1/4 NPTF CYCLES 7 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 20 GPM PEAK (25 PSI DROP) 26 GPM W BACK CV (FLOW AT 1 PSI DROP) 5.0 OF VALVE WITHOUT MAX. BACKWASH (25 PSI DROP) 7 GPM COVER REGENERATION DOWNFLOW/UPFLOW BOTH PRODUCT FEATURES ADJUSTABLE CYCLES BRINE FLOW ONLY TIME AVAILABLE 180 MINUTES SIMPLE MECHANICAL DESIGN IS EASY TO UNDERSTAND METER INFORMATION TWO VALVE BODY DESIGNS: ONE FOR DOWNFLOW REGENERATION METER ACCURACY RANGE .25 - 15 GPM +/- 5% AND ONE FOR U...
MODEL 5600 MECHANICAL CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL NORYL®* INLET/OUTLET 3/4, 1, 1-1/4 NPTF CYCLES 7 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 20 GPM PEAK (25 PSI DROP) 26 GPM W BACK CV (FLOW AT 1 PSI DROP) 5.0 OF VALVE WITHOUT MAX. BACKWASH (25 PSI DROP) 7 GPM COVER REGENERATION DOWNFLOW/UPFLOW BOTH PRODUCT FEATURES ADJUSTABLE CYCLES BRINE FLOW ONLY TIME AVAILABLE 180 MINUTES SIMPLE MECHANICAL DESIGN IS EASY TO UNDERSTAND METER INFORMATION TWO VALVE BODY DESIGNS: ONE FOR DOWNFLOW REGENERATION METER ACCURACY RANGE .25 - 15 GPM +/- 5% AND ONE FOR U...
MODEL 1500 .75 RESIDENTIAL CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS MANUAL CONTROL OPTION VALVE MATERIAL LEAD-FREE BRASS* W INLET/OUTLET 3/4 NPTF CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 17 GPM PEAK (25 PSI DROP) 22 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 14 GPM REGENERATION DOWNFLOW/UPFLOW DOWNFLOW ONLY PRODUCT FEATURES ADJUSTABLE CYCLES YES TIME AVAILABLE 164 MINUTES FULLY ADJUSTABLE 5-CYCLE CONTROL DELIVERS CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW RINSE, RAPID RINSE, METER INFORMATION BRINE REFILL AND DOWN...
MODEL 9000 RESIDENTIAL TWIN TANK CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL LEAD-FREE BRASS** INLET/OUTLET 3/4, 1 OR 1-1/4 W FRONT WITHOUT COVER CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE FLOW RATE (50 PSI INLET) 1 METER 3/4 METER CONTINUOUS (15 PSI DROP) 21 GPM 18 GPM PEAK (25 PSI DROP) 28 GPM 24 GPM CV (FLOW AT 1 PSI DROP) 5.1 4.8 MAX. BACKWASH (25 PSI DROP) 8.5 GPM 8.5 GPM REGENERATION W BACK WITHOUT COVER DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES TIME AVAILABLE 164 OR 82 MINUTES PRODUCT FEATURES METER INFORMATION FULLY ADJUSTABLE 5-CYCLE CONTROL DELIVERS CONTROLL...
MODEL 2510 CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS BACK VALVE MATERIAL FIBER REINFORCED POLYMER W INLET/OUTLET 3/4, 1 OR 1-1/4 CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 19 GPM PEAK (25 PSI DROP) 24 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 17 GPM REGENERATION PRODUCT FEATURES DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES FULLY ADJUSTABLE 5-CYCLE TOP MOUNT CONTROL DELIVERS TIME AVAILABLE ELECTROMECHANICAL: 164 MINUTES CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW SE: 0 - 99 MINUTES RINSE, RAPID RINSE, BRINE REF...
MODEL 2510 CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS BACK VALVE MATERIAL FIBER REINFORCED POLYMER W INLET/OUTLET 3/4, 1 OR 1-1/4 CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 19 GPM PEAK (25 PSI DROP) 24 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 17 GPM REGENERATION PRODUCT FEATURES DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES FULLY ADJUSTABLE 5-CYCLE TOP MOUNT CONTROL DELIVERS TIME AVAILABLE ELECTROMECHANICAL: 164 MINUTES CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW SE: 0 - 99 MINUTES RINSE, RAPID RINSE, BRINE REF...
MODEL 2510 CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS BACK VALVE MATERIAL FIBER REINFORCED POLYMER W INLET/OUTLET 3/4, 1 OR 1-1/4 CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 19 GPM PEAK (25 PSI DROP) 24 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 17 GPM REGENERATION PRODUCT FEATURES DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES FULLY ADJUSTABLE 5-CYCLE TOP MOUNT CONTROL DELIVERS TIME AVAILABLE ELECTROMECHANICAL: 164 MINUTES CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW SE: 0 - 99 MINUTES RINSE, RAPID RINSE, BRINE REF...
MODEL 4650 HOT WATER CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL LEAD-FREE BRASS* W FRONT WITHOUT COVER INLET/OUTLET 3/4, 1 OR 1-1/4 BACK WITHOUT COVER W CYCLES 7 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 20 GPM PEAK (25 PSI DROP) 26 GPM CV (FLOW AT 1 PSI DROP) 5.2 MAX. BACKWASH (25 PSI DROP) 7 GPM REGENERATION PRODUCT FEATURES DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES BRINE FILL ONLY DESIGNED WITH DOUBLE BACKWASH TIME AVAILABLE 180 MINUTES HOT WATER CAPABILITY DIMENSIONS COMBINES RUGGED, LEAD-FREE BRASS BODY WITH TIME-TESTED DISTRIBUTOR PILOT 1.05 PIPE O...